ISSN 2149-0287
Bosphorus Medical Journal Correlation Between Internal Jugular Vein/Common Carotid Artery Ratio And Central Venous Pressure [Bosphorus Med J]
Bosphorus Med J. 2017; 4(3): 117-120 | DOI: 10.15659/bogazicitip.17.10.743

Correlation Between Internal Jugular Vein/Common Carotid Artery Ratio And Central Venous Pressure

Burcu Azapoğlu Kaymak1, Turgut Deniz2, Ünase Büyükocak3, Aliye Öztürk4
1University of Health Sciences Fatih Sultan Mehmet Education and Research Hospital Emergency Department, Istanbul
2Kirikkale University Faculty of Medicine, Department of Emergency Medicine, Kirikkale, Turkiye
3Koru Hospitals, Department of Anesthesia and Reanimation, Ankara, Turkiye
4Kastamonu State Hospital, Department of Anesthesia and Reanimation, Kastamonu, Turkiye

INTRODUCTION: The aim of this study was to evaluate a rapid and non-invasive method for estimating central venous pressure (CVP) by comparing ultrasound measurements of the internal jugular vein and common carotid artery to CVP measured by central venous catheter
METHODS: A portable ultrasound machine was used to determine cross-sectional areas of the internal jugular veins (IJV) and common carotid arteries (CCA). The measurements were performed on patients lying in the supine position at a 45 degree angle, with ratios of the IJV area to CCA area recorded as ratio 1(lying position) and ratio 2(45˚ position). The patients were categorized
into 3 groups according to CVP, specifically; group1: CVP<10mmHg, group2: CVP 10-20mmHg, and group3: CVP>20mmHg.
RESULTS: Forty intensive care unit patients who were mechanically ventilated with a central venous catheter in place were enrolled during the study period. No statistically significant differences detected in ratio 1. Ratio 2 showed a mean ratio of 1.18 for group 1(min-max 0.72-1.64),2.64 for group 2 (min-max 1.73-3.55) and 3.00 for group 3 (min-max 0.97-5.03). For ratio 2, it was observed that group 1 had a lower value than group 2 (p=0.020) and group 3 (p=0.021).
DISCUSSION AND CONCLUSION: Ultrasound measurement of internal jugular to common carotid area ratio at a position of 45 degrees showed that a low ratio was correlated with a low central venous pressure as measured by central venous catheter.

Keywords: ultrasound; central venous pressure; non invasive; intensive care

Internal Juguler Ven/Karoti̇s Arter Oranının Santral Venöz Basınç ile İli̇şki̇si

Burcu Azapoğlu Kaymak1, Turgut Deniz2, Ünase Büyükocak3, Aliye Öztürk4
1University of Health Sciences Fatih Sultan Mehmet Education and Research Hospital Emergency Department, Istanbul
2Kirikkale University Faculty of Medicine, Department of Emergency Medicine, Kirikkale, Turkiye
3Koru Hospitals, Department of Anesthesia and Reanimation, Ankara, Turkiye
4Kastamonu State Hospital, Department of Anesthesia and Reanimation, Kastamonu, Turkiye

GİRİŞ ve AMAÇ: Çalışmanın amacı santral venöz basıncı (SVB) karotis arter ve internal juguler venin ultrason ölçümlerini santral venöz kateter yoluyla ölçülmüş SVB ile karşılaştırarak hızlı ve non invaziv bir yöntemle değerlendirmek.
YÖNTEM ve GEREÇLER: Ultrason ile internal juguler ven (IJV) ve karotis arterin (KA) alan ölçümleri yapıldı, oranları hesaplandı. Ölçümler hastalar supin ve 45o yatar pozisyondayken yapıldı ve ölçüm sonuçları supin pozisyonda yatanlar için ‘oran1’ ve 45o yatar pozisyon için ‘oran2’ olarak kaydedildi. Hastalar SVB değerlerine göre üç gruba ayrıldı: Grup 1: SVB < 10 mmHg, Grup 2 SVB 10-20 mmHg, Grup 3: SVB > 20 mmHg.
BULGULAR: Çalışmaya çalışma sürecinde yoğun bakım ünitesinde yatmakta olan, invaziv mekanik ventilatörde takipli santral venöz kateteri olan 40 hasta dahil edildi. Oran1’de gruplar arası anlamlı fark tespit edilmedi. Oran2 ‘de grup 1’de ortalama 1.18 (min-max 0.72- 1.64), grup 2’de 2.64 (min-max 1.73-3.55) ve grup 3’de 3.00 (min-max 0.97-5.03) izlendi. Oran2’nin grup 1’de grup 2 ve 3’e göre daha anlamlı olduğu izlendi.
TARTIŞMA ve SONUÇ: 45o yatar pozisyonda yapılan ultrason ölçümleriyle elde edilen İJV/KA oranının (oran2) santral venöz basıncı düşük ölçülmüş hasta grubunda (grup1) korelasyonunun daha iyi olduğu tespit edildi.

Anahtar Kelimeler: ultrason; santral venöz basınç; noninvaziv; yoğun bakım

Burcu Azapoğlu Kaymak, Turgut Deniz, Ünase Büyükocak, Aliye Öztürk. Correlation Between Internal Jugular Vein/Common Carotid Artery Ratio And Central Venous Pressure. Bosphorus Med J. 2017; 4(3): 117-120

Corresponding Author: Burcu Azapoğlu Kaymak
Manuscript Language: English